Products
Product Description

Single Lamp Controller
DHT-G-11PU/ 22PU/ 33PU
RS485/CAT1/HPLC
Product Features
The DH-G series single lamp controller is a control terminal designed specifically for individual street lights, capable of various control modes such as time control, manual control, and intelligent switching control modes, intelligently adjusting the brightness and switching of street lights to achieve on-demand lighting. The control module uses LteCat1/RS485/HPLC signals for data transmission, directly connecting to the server for backend software management and control of individual lamps. The controller automatically detects the working status of the lamp and promptly reports alarms in case of abnormalities, allowing precise fault localization of the street light system.It detects the working status of the lamp, and in case of abnormal operation, it promptly reports alarms, allowing precise fault localization of the street light system.
Product Functions
Communication Function: UsesLteCat1/RS485/HPLC and othercommunication methods, with stable signals and fast transmission efficiency, equipped with lightning protection and surge protection functions.。
Power Collection: Real-time monitoring of street light voltage, current, power, energy, and lighting duration statistics.
Intelligent Control: Achieves remote broadcasting of street lights./Multicast/Unicast switch control, brightness adjustment, time segment control, geographic coordinate control, system task control, and task self-execution.
Fault Detection: Uses intelligent algorithms to detect the working status of street lights, with abnormal alerts for easy monitoring and maintenance of the fixtures. Leakage and pole tilt detection (customizable).
Peripheral Interface: Supports1Input;220VACOutput;1Input;220VACand1Input;0V-10VPWM1Input;interfaces (customizable isolated dimming).Dimming Method: Supports
stepless dimming, choose any one.interfaces (customizable isolated dimming).PWM0V-10VFirmware Upgrade: Remote
HTTPupgrade.Waterproof Rating: Uses
protection rating.IP67Applicable Environment: Uses high-quality waterproof thermal conductive silicone, with good temperature adaptability, can operate normally in
-40°C ~ +80°Cenvironment.环境下正常工作。
Communication Protocol: Supports multiple protocols, supports standardModBusprotocol and proprietary protocols, supportsMQTTcommunication methods.
Technical Parameters
| Product Model | DH-G-11PU | DH-G-22PU | DH-G-33PU |
| Voltage Range | 85V-305VAC | ||
| Frequency Range | 50HZ/60Hz | ||
| Current Range | 0A-4A | ||
| Standby Power Consumption | <1W | ||
| Voltage Detection Range | 85V-305VAC | ||
| Voltage Detection Accuracy | ≤2% | ||
| Current Detection Range | 0A-2.5A | ||
| Current Detection Accuracy | ≤2% | ||
| Active Power Detection Accuracy | ≤2% | ||
| Dimming Output PWM | 5V/400Hz | ||
| Dimming Output 0-10V | 0V-10V (accuracy 1%) | ||
| Communication Method | Lte Cat1 | RS485 | HPLC (Power Line Carrier) |
| Communication Rate | 115200bps | 9600bps | Uses OFDM technology |
| Operating Temperature | -40°C~+80℃ | ||
| Operating Humidity | 5%~90%RH (no condensation) | ||
| Storage Temperature, Humidity | '-40℃~+85℃/10~90%RH | ||
| Safety Standards | UL8750, EN61347-1, CLASS2, IP67, UL60950-1 | ||
| Withstand Voltage | I/P-0/P:3.75KVAC I/P-FG:2KVAC 0/P-FG:0.5KVAC | ||
| Insulation Resistance | I/P-0/P, I/P-FG, 0/P-FG 50MQ At 500VDC | ||
| Electrostatic Discharge | IEC/EN61000-4-2 Contact±4KV/Air±8KV | ||
| Impulse Group Immunity | IEC/EN61000-4-4±4KV | ||
| Surge Immunity | IEC/EN 61000-4-5 Power Line: line to line 4 KV, line to earth 6 KV | ||
| Protection Level | IP67 | ||
| Dimensions | L*W*H=168*56*40mm | ||
| Net Weight | 350g | ||
Welcome your message consultation